Translation

Addressing freeze protection in NFPA 13D

title

By Fred Durso, Jr.

One of the common concerns for homeowners that have a sprinkler system in compliance with NFPA 13D, Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, is the potential for frozen pipes. The Residential Sprinkler Systems Technical Committee, which is responsible for the development of NFPA 13D, has provided allowances to omit sprinklers in the parts of a home that are most susceptible to freeze protection concerns. This includes attic spaces, garages, and vestibules. These spaces are commonly left unheated to help keep costs down for the homeowner, and are therefore exposed to lower ambient temperatures.

The reason these spaces do not require sprinklers is not limited to freezing concerns; fires originating in these areas have not been known to lead to loss of life. As discussed in my previous blog post, one of the fundamental principles of NFPA 13D is that it is a life-safety system. Property protection is not the primary function of this system.

There are many methods that sprinkler designers and architects can employ to eliminate concerns over frozen pipes. The standard addresses the use of heat tracing, heating spaces, insulation, dry systems, and dry sprinklers as viable options.

While dry systems are not always a first choice for designers due to the additional maintenance commonly associated with drive valves, the use of dry heads is certainly something to consider. There are now dry residential heads on the market, and they have been effective in eliminating freeze protection concerns.

No matter what path is taken to provide freeze protection, should the homeowner have any concerns, it is important to discuss these issues with the system designer or service provider. Shutting off the system control valve over freezing fears is not the solution.

Matt Klaus is NFPA’s principal fire protection engineer and staff liaison for NFPA 13D. Klaus is a regular contributor to this blog and discusses the technical components of home fire sprinklers.

Source:: NFPA – Fire Sprinkler Initiative

Michael S. Williams

Michael S. Williams

Williams founded the Fire Services Training Institute in 1995 to find solutions to the challenges confronting the volunteer fire service. He has been an active member of California State Firefighters Association (CSFA) since 1994, having served on the volunteer and public relations committees, and as a southern division deputy director. He sits on several local organizations including the Santa Barbara County Fire Safe Council, the Tri-Counties Training Officers Association, Santa Barbara Chapter of CAER and is a founding member of the Santa Barbara PIO group Emergency Public Information Communicators (EPIC). He has been the author of many articles and a columnist for a local newspaper on public safety matters. He is also the co-host of Community Alert on KZSB AM-1290 in Santa Barbara. Williams has been a member of the California State Board of Fire Services since 2008. Prior to becoming involved in the volunteer fire service, Williams was a California police officer for 12 ½ years and a POST certified Field Training Officer. He is a licensed private investigator and security consultant specializing in self-insured, government and insurance defense assignments.


Related Articles

Dementia care expert joins NFPA committee to address concerns of unique high risk populations

By nfpa@jiveon.com I’d like to introduce Linda Farrar, who has joined the NFPA Unique High Risk Populations Advisory Committee. The…

Recent home fire is another example of flaws in traditional fire suppression efforts

By nfpa@jiveon.com Kaylee Gaydon and Noah Gaydon (Photo Credit: Channel 2 Action News) A recent fire in the news triggered…

Fire Protection Research Foundation announces winners of the 2016 William M. Carey and Ronald K. Mengel Awards

The Fire Protection Research Foundation (Foundation), an affiliate of the National Fire Protection Association (NFPA), announced winners of the 2015…